! RLH Industries, Inc.Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com! Page 1
RLH iMux System
MODULAR 16x1 VOICE AND DATA
MULTIPLEXED OVER FIBER OPTICS
The iMux is a powerful fiber optic modular multiplexer capable of
providing up to 16 channels of E1, T1, V.35 (RS530), X.21, RS232,
2/4 wire analog data/SCADA/E&M and analog phone FXO/FXS
services, plus four built-in 10/100M Ethernet ports, over a single fiber.
These services are supplied by iMux 4x1 modules that plug into the
back of the unit. Each module has 4 ports, and up to 4 modules may
be installed in any combination. Spares or add-on modules may be
ordered separately and installed by the end user, and may be used
with leased lines to build up private networks, private telephone
networks (by interconnecting PBX's) or access the internet or a
partner network (extranet). A typical complete system comprises of
one FXO and one FXS module, or use an FXS unit at each end for
ringdown operation where direct connection to phones on both ends
of the system is desired.
The optical modules are installed into the front of the unit. Both dual
fiber and single bi-directional fiber (WDM) optical modules are
available, and up to 2 optical modules may be installed, providing 1+1
hot-swappable optical protection and making the best use of fiber
availability.
The iMux may be managed through SNMP, web Interface, VT100 craft
port or LCD/menu keys on the front panel. It also has an external
alarm port for alarm input monitor purposes, and an alarm port with
four alarm contacts. The system provides local/remote loopback
functions for optical and E1 interfaces, and is ideal for network testing
and maintenance.
The iMux takes up 1RU and comes complete with EIA19” and 23”
rack ears, or it may be used on a desktop or shelf.
PI-003 2013B-1014
Standard Features
Multiplexes up to 16 voice and data channels plus
Ethernet over a single fiber
Up to 4 modules (each with 4 ports) may be used in any
combination to mix and match services
Convenient front LED status indicators
E1, T1, V.35, RS530, X.21, RS232, FXO/FXS, 2/4 wire
Analog Data/SCADA/E&M & 10/100Base-T Ethernet
port options
Aggregated Ethernet throughput up to 100Mbps
Supports VLAN/QOS and port rate control
Optical module auto laser shutdown (ALS), hot swappa-
ble 1+1 protection
Alarm relay has major and minor alarms (audible and
visible alarm output )
Supports SNMP , HTTP / FTP / TFTP remote software
upgradeable
Supports TELNET function to configure and monitor
local and remote devices through TCP/IP network
Provides the parity error count for optical interface per-
formance monitoring
Includes optical line local loopback and remote loopback
functions
An Embedded Operation Channel (EOC) is maintained
between local and remote sides for system configuration,
testing, performance and alarm monitoring of each E1
channel and optical link
External clock (Optional): E1 external TTL clock or PCM
data Input through DB-9 connector
Class 1 Laser optical module is safety standard IEC 825
compliant
Available with ringdown circuit operation
Redundant 48VDC or AC/DC powering options
RLH iMux with dual optics modules
The leader in
rugged fiber optic
technology.
PRODUCT INFORMATION
RLH Industries, Inc.
Przeglądanie stron 0
1 2 3 4 5 6 7 8

Podsumowanie treści

Strona 1 - RLH iMux System

! RLH Industries, Inc. • Tel. 866-DO-FIBER • Fax 714 532-1885 • www.fiberopticlink.com! Page 1RLH iMux SystemMODULAR 16x1 VOICE AND DATAMULTIPLEXED OVE

Strona 2 - Module Specifications

Module SpecificationsT1 Interface ModuleT1 Interface ModuleChannel capacity(4)T1Bit Rate1.544Mbps ± 32ppmLine CodeB8ZS/AMIFrame FormatSF, ESF, Unframe

Strona 3

Module SpecificationsiMux user installable module. Analog POTS module shown.2/4 Wire Analog Data/Audio/SCADA Module2/4 Wire Analog Data/Audio/SCADA M

Strona 4 - General Specifications

General SpecificationsGeneral SpecificationsGeneral SpecificationsAlarm Contacts4 relay contacts (DB-9 connector)External AlarmDB-9 connectorCompliance

Strona 5 - Ordering Information

Ordering InformationBase SystemsPart NumberDescriptionPower 1Power 2Dimensions (1RU) RLH-IMUX-V-2iMUX BASE SYSTEM DUAL 48 VDC INPUT PWR48VDC48VDCW17.3

Strona 6

iMux OpticsPart NumberDescriptionSideDistanceFiberPart NumberBi-DirectionalMultimode SCiMux Optical ModuleA2 km/1.2 mi62.5 μmRLH-OM-01-1Bi-Directiona

Strona 7 - Contact Information

WarrantyRLH is recognized throughout the U.S. in the telecommunications industry for our experience and we stand with total confidence in our quality.

Strona 8 - T: (714) 532-1672

RLH Industries, Inc.936 N. Main Street, Orange, CA 92867 USAT: (714) 532-1672F: (714) 532-1885Please contact your RLH sales representative for pri

Komentarze do niniejszej Instrukcji

Brak uwag