RLH Industries 16 Channel T1 Over Ethernet Multiplexer System Dokumentacja Strona 1

Przeglądaj online lub pobierz Dokumentacja dla Konwertery mediów sieciowych RLH Industries 16 Channel T1 Over Ethernet Multiplexer System. RLH Industries 16 Channel T1 Over Ethernet Multiplexer System Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - Quick Start Guide

iMux Fiber OpticMultiplexer SystemQuick Start GuideQS-001 2014A-0911RLH Industries, Inc.

Strona 2

Rear PanelAny of the modules may be plugged into any position, called a Tributary Slot. These are referred to as TB1~TB4.Refer to the Specifications s

Strona 3 - Contents

4 Channel RS-232 Module4xRS-232 module, HD68 to 4 DB-9 connectors to RS-232 interface. Breakout adapter cable is included.10(f) RS232 tributary card A

Strona 4

4 Channel Analog Phone (POTS) ModulesAnalog phone uses RJ-11 connectors and are supplied as FXS/Sub side and FXO/CO side modules.The FXO/CO module is

Strona 5 - Laser Safety

4 Channel 2/4 Wire Analog Data/Audio/SCADA ModuleFour Analog 2/4 Wire Data/Audio/SCADA modules use RJ-11 connectors.Each channel has 300Hz ~ 3.4kHz ba

Strona 6 - 2." Introduction

Setting E&M Jumpers and SwitchesUse the J2 jumper and the J4 DIP switches to set the E&M module mode to Master or Slave depending on the place

Strona 7 - Application Diagrams

detectOff-hookOff-hookOn-hookOn-hookEMGNDTRT14-WireAudio4-WireAudioTrunk CircuitSignalling Unit4 Wire E&M Card - MasterR1E7682354MT(-48V)Fiber Opt

Strona 8 - Front Panel

AcronymsCommonly used acronyms and abbreviationsAcronym/AbbreviationDescriptionB8ZSBipolar 8 Zero SubstitutionFXO/COCentral Office Side EquipmentFXS/Su

Strona 9 - LAN1 LAN2 LAN3 LAN4 MGMT

3." Before InstallingObserve Special Handling RequirementsBe careful when handling electronic componentsATTENTIONELECTROSTATICSENSITIVEDEVICES• T

Strona 10 - 4 Channel T1 Module

Prepare for InstallationCheck for shipping damageCarefully unpack and inspect the unit and accessories. Contact RLH immediately if any components are

Strona 11 - 4 Channel V.35 Module

Typ i ca l a pp l ic at i on en vi ro nm e nt sInstall the fiber optic cable prior to installing the iMux system.Required power sourcesYou will nee

Strona 12 - 4 PIN RJ-11

RLH Industries, Inc.Copyright © 2013 RLH Industries, Inc. All rights reserved.No part of this document may be copied or distributed without permissio

Strona 13 - PIN 8PIN 1

4." Quick StartEasy InstallationBefore starting•Review the safety information in section 1. Important Information•Familiarize yourself with the i

Strona 14

Connect ethernet cables• Attach ethernet cables to the RJ-45 ethernet ports labeled LAN1 through LAN4 on the front panel of the iMux.Connect data/phon

Strona 15 - E&M Application Diagram

5." SpecificationsGeneral SpecificationsAlarmContact Capacity4 relay contacts (DB-9 connector)AlarmExternal AlarmDB-9 connectorPower SupplyAC115/2

Strona 16 - Acronyms

Service Module SpecificationsT1 Interface ModuleChannel Capacity4 x T1T1 Interface ModuleBit Rate1.544 MbsT1 Interface ModuleLine CodeB8ZS per ANSI T1

Strona 17 - 3." Before Installing

6." Ordering InformationBase SystemsPart NumberDescriptionPower 1Power 2Dimensions (1RU) RLH-IMUX-V-2iMUX BASE SYSTEM DUAL 48 VDC INPUT PWR48VDC4

Strona 18 - Site Requirements

Optical ModulesPart NumberDescriptionSideDistanceFiberPart NumberMultimode STiMux Optical Module-2 km/1.2 mi62.5 μmRLH-OM-04-1Bi-DirectionalSingle-mo

Strona 19 - Tes t Eq ui pm en t

7." SupportTec hn ic al S up po rtEmail:support@fiberopticlink.com24/7 technical support:Toll Free 1-855-RLH-24X7Toll Free 1-855-754-2497Contact

Strona 20 - 4." Quick Start

Contents1." Important InformationIntended Audience! 5Conventions! 5General Safety Practices! 52." IntroductionProduct Description! 6Standard

Strona 21 - Start the system

Prepare for Installation! 18Check for shipping damage# 18Verify system contents # 18Verify matching optical module and fiber modes# 18Site Requirements

Strona 22 - 5." Specifications

1." Important InformationIntended AudienceThis manual is intended for use by knowledgeable telco/network installation, operation and repair perso

Strona 23 - Service Module Specifications

2." IntroductionProduct DescriptionThe iMux is a powerful fiber optic modular multiplexer capable of providing up to 16 channels of T1, RS232, 2/

Strona 24 - 6." Ordering Information

Application DiagramsT1T12/4 WireDataRS-232 RS-232Ethernet(VLAN/QoS)Ethernet(VLAN/QoS)2/4 WireDataPOTS(FXS)POTS(FXO)RLH iMux RLH iMuxLAN1 LAN2 LAN3 LAN

Strona 25 - Optical Modules

Front PanelRSTMAJMINLBKRDIPWRLCKACOLOS/LOF/AIS123 41234E1/V35EXT CLK CRAFT SL-2100TX RXWKLOSLSRONTX RXWKLOSLSRONLAN1 LAN2 LAN3 LAN4 MGMTFront Panel LE

Strona 26 - 7." Support

Module Status LEDsRSTMAJMINLBKRDIPWRLCKACOACOLOS/LOF/AIS1 2 3 41234E1/V35PORTSCRAFT TX RXWKLOSLSRTX RXWKLOSLSRLAN1 LAN2 LAN3 LAN4 MGMTIMux slot num